Specs & quotes / Gloss and matt finish
SPC flooring gloss level: how to specify a matt finish that repeats
Name the geometry, target and tolerance: ISO 2813 reads gloss at 20°, 60° or 85°, and its scope covers non-textured coatings only.
Short answer
Write the finish as a gloss value at a named geometry, with a tolerance, measured by a named method on agreed spots of the board. Back it with labelled reference planks held by both sides and a fixed lighting set-up for the visual check. For a matt floor, record 85° beside 60°. Take the target from the approved boards themselves; the measuring standards set no limit for floors.
ISO 2813:2014, confirmed in 2025, measures gloss at 20°, 60° or 85° and is written for non-textured coatings on plane, opaque substrates, so on an embossed SPC face its readings are comparative only.
The withdrawn 1994 edition of ISO 2813 described the 85° geometry as giving better differentiation between low-gloss films; a matt floor needs that reading beside the 60° one.
ASTM D523-25 notes that visual and instrument gloss differences may stop tracking each other when specimens differ widely in gloss or colour, which is a reason to set tolerances per decor.
“Matt” on a purchase order is an adjective, and two factories, or two lots from one factory, can both meet it. A finish that repeats needs a number with an angle, a tolerance, physical reference boards and an agreed way of looking.
What should a gloss line in an SPC specification contain?
Five things: the geometry, the target value, the tolerance, the measuring method with its conditions, and the reference planks the reading is compared with. Leave any one out and the line cannot settle a dispute. A number with no angle is not a specification, and a specification with no retained boards has nothing to be compared with on the next order.
The template below is our method. The blanks are deliberate: ISO 2813 and ASTM D523 are measuring methods and set no gloss target or tolerance for a floor, so the values come from your approved boards.
| Field | What to write | Why it is there |
|---|---|---|
| Geometry | 60° and 85° for a matt face; add 20° only for a high-gloss face | One angle cannot separate matt finishes |
| Target | [] GU at 60°; [] GU at 85°, each the mean of the approved boards’ readings | Ties the number to boards both sides hold |
| Tolerance | ± [] GU at each geometry, per decor; applies to the mean of [] readings per board, to each board, and to the lot as [__] boards sampled | Agreed, not borrowed from another product; says which value fails a lot |
| Method | ISO 2813:2014 or ASTM D523-25, named; instrument and calibration date recorded | Two methods, two sets of rules; pick one |
| Spots and direction | [] boards per lot, [] readings per board, along and across the grain, at marked positions | Embossing makes the reading depend on where and which way |
| Reference | Planks [ID], retained by buyer and factory, read in the same session as the lot | A drifting instrument shows up on the reference too |
| Visual check | Lamp, viewing angle and approver named (see below) | Decides what the number cannot |
Write the line once, in the specification annex, and refer to it from the purchase order. The sample-to-specification process that holds this line, and the other construction fields beside it, is covered in turning an approved sample into a written specification.
Which glossmeter geometry suits a matt SPC floor?
Read 85° beside 60°. The 60° geometry is the general one; the 85° geometry looks at the board close to grazing, where low-sheen faces that read alike at 60° can still be told apart. 20° belongs to high-gloss surfaces. As of November 2026, ISO 2813:2014 and ASTM D523-25 both cover all three geometries.
The table sets out what each source says about the three angles and how we would use them on SPC.
| Geometry | What the source says | Use on SPC |
|---|---|---|
| 20° | ISO 2813:1994 abstract: improved differentiation between high-gloss films | High-gloss or lacquered faces only |
| 60° | ISO 2813:1994 abstract: applicable to all paint films | Always record it, so every report has one common reading |
| 85° | ISO 2813:1994 abstract: improved differentiation between low-gloss films | The working reading for matt and ultra-matt faces |
The selection wording comes from the withdrawn 1994 edition, because the abstract of the current edition does not restate it; check the purchased 2014 text before quoting a threshold in a contract. If a factory report gives only one reading on a matt decor, ask for the other.
How do embossing and the UV coat change the reading?
Both move it. ISO 2813:2014 is written for non-textured coatings on plane, opaque substrates; on other specimens, it says, gloss values are comparative and may not match what the eye sees. An embossed SPC face is such a specimen. And ASTM D523 states that readings change with the refractive index of the surface, so a different coat chemistry can shift the number.
In practice that means three things for the specification. First, readings on an embossed face only compare like with like: the same spots, the same direction relative to the grain, the same instrument. Second, gloss is set by the emboss and the top coat together, so a change of emboss plate or UV lacquer is a change of finish and goes back to sampling, not to a gloss check alone. Third, ASTM D523 notes that distinctness of image, haze and texture also enter the visual impression of gloss, which is why the visual check below stays in the specification even when the numbers agree.
Embossed in register, licensed matt technologies and the decor print itself are separate choices; how a decor is matched from a photo to a printed film is covered in our guide to decor film from a reference image. Where the factory names a branded matt process, ask for it as a named field, as the specification guide sets out.
What should the retained reference planks carry?
A label, a reading and a twin. Each reference plank carries a unique ID, the decor and production lot, the date, both sides’ signatures and its gloss readings at the agreed spots, which are marked on the plank. The factory keeps one set; you keep a matching set. Every later reading of a lot is taken with a reading of the factory’s set in the same session.
Why both sets: a glossmeter can drift, and an instrument reading the lot alone cannot tell drift from a change in the lot. A reference read in the same session shows whether the instrument or the boards moved. Store the planks flat, boxed and out of daylight, so the reference stays as it was approved.
The first production boards make the best references, not the pre-production sample, because they come off the line that will make the order. The factory’s in-line gloss check against that master belongs in the production hold points, recorded per shift, so a drift is caught before boxes are packed.
How do you set up the visual comparison?
Fix the light, the angle, the distance and the person before the first lot. ASTM D4449 is the visual gloss method: it uses a lamp giving strong light-and-dark contrast, identifies six types of gloss and grades four levels of difference. ASTM D1729 sets the conditions for visual colour comparison under diffuse light, with simulated daylight D65 recommended. Gloss and shade need different light.
The table puts the two checks side by side. Name both in the specification, with the equipment you will use.
| Check | Light | What it finds | Standard to name |
|---|---|---|---|
| Gloss difference | Lamp giving strong light-and-dark contrast (D4449); we add a low viewing angle, as in a corridor | Sheen bands, patchy coat, haze | ASTM D4449-15(2021) |
| Colour and shade | Diffuse simulated daylight D65 | Shade difference between lots | ASTM D1729-22 |
Lay the boards as they will be laid: lot boards beside reference planks, same direction, several boards wide, so a band across a room shows as it would on site. D1729 assumes trained observers with good colour vision; name the person on each side who signs the comparison. The pre-shipment inspector carries the same set-up into the lot check; our pre-shipment inspection checklist has gloss and colour against the master board as an essential check.
What happens when a lot does not match?
Hold it before packing, measure the lot and both reference sets in one session, then compare under the agreed light. If the readings sit inside tolerance and the visual check passes, the lot ships. If either fails, the contract decides: rework, downgrade or reject. Whether a finished board can be re-coated is the factory’s call; agree it in writing before it is offered as a remedy. Without a written order of tests, the argument has no end.
The flow below is our method; put it in the specification annex so both sides know it before the first lot.
| Step | Who | Evidence |
|---|---|---|
| 1. Notify before packing | Factory QC or your inspector | Readings, spots, instrument, date |
| 2. Joint reading | Both sides, same instrument | Lot readings and both reference sets, one session |
| 3. Visual comparison | Named approvers | Boards laid side by side under the agreed lamp, photographed |
| 4. Decision | You | Accept, rework as agreed in writing, downgrade or reject, as the contract states |
| 5. Record | Both sides | Signed note added to the lot file and the reference set |
If a mismatch is found after arrival, the claim rests on the same evidence: your reference planks, readings in one session and the visual comparison. Notice periods and how to build that claim are covered in our guide to claims on a defective container.
Worked example: 60° passes, 85° catches a lacquer change
Illustrative only. A UK distributor runs an ultra-matt oak decor. The approved first-production boards read 2.0 GU at 60° and 5.5 GU at 85°; the specification sets ± 1.0 GU at 60° and ± 2.0 GU at 85°, both agreed from those readings. Three planks per side are retained.
On the third lot the factory’s 60° readings sit inside tolerance. The 85° readings average 9.0 GU, and the factory’s own reference set reads 5.6 GU on the same instrument that afternoon, so the instrument has not drifted. Under the agreed lamp, at a low angle, the lot shows a visible sheen against the references. The factory traces it to a new drum of UV lacquer. Because the specification names 85° and the hold step, the lot is stopped before packing, the affected boards are replaced under the rework terms agreed in writing, and the replacement boards read 5.8 GU at 85°. A 60° reading alone would have passed the lot, and the first sign would have been a long corridor at the end customer’s site.
Our view
We would never accept “matt” or a single unlabelled gloss figure on a specification. Tolerances are a negotiation, but they are per decor, because ASTM D523 warns that numbers and eyes stop agreeing when specimens differ widely in gloss or colour.
On a repeat order, the reference planks matter more than any number on the factory’s data sheet. Our product development work writes these lines into the specification with you; the full set of guides on building a specification is in specs and quotes.
Common mistakes with gloss and matt finishes
Most gloss disputes we would guard against start with a line that names no angle or a reference that only one side kept. The table lists the usual ones, what each costs and how to avoid it.
| Mistake | What it costs | How to avoid it |
|---|---|---|
| “Matt” or “low gloss” with no number | Any lot meets the words | Value, geometry, tolerance and method in the annex |
| Only a 60° reading on a matt decor | Sheen differences pass unseen | Add 85° |
| Target taken from a brochure | Approved boards fail their own spec, or worse boards pass | Target from the approved boards’ readings |
| Reference planks kept by the factory only | No way to check drift or swaps | Twin sets, labelled and signed |
| One tolerance for every decor | Dark and light decors look different at the same spread | Set tolerance per decor |
| Lacquer or emboss plate changed without notice | New finish on a running decor | Treat as a change needing a new sample |
| No order of tests | Readings and eyes disagree, nobody decides | Written dispute flow in the annex |
Questions buyers ask
Can I ask the factory to send gloss readings with every lot?
Yes, and it costs the factory little if a glossmeter already sits on the coating line. Ask for the readings at the agreed geometries and spots, the instrument and its calibration date, and the same readings taken on the factory's retained reference planks on the same day. A lot reading without a reference reading beside it tells you less.
What happens if the readings pass but the boards look different?
Then the contract has to say which test decides. If it is silent, you are arguing a number against your eyes. We would write that the instrument reading is the first gate and the agreed visual comparison against the reference planks decides appearance, because the end customer judges with eyes, not a glossmeter.
Does a gloss figure on a factory data sheet mean anything?
Only if it states the geometry, the method and where on the board it was read. "Gloss 5" with no angle cannot be compared with another factory's figure or with your own reading, and on an embossed face the spot and direction can move the number.
Can the factory change its UV lacquer supplier on a running decor?
Treat it as a change that needs a new sample. ASTM D523 states that readings change with the refractive index of the surface, so a different coat can read differently at the same visible sheen, or look different at the same reading. Ask for boards from the new coat measured beside the reference planks before it goes on your order.
Can we measure gloss ourselves when the container arrives?
Yes, if you use the same geometries, a calibrated instrument and the same spots and direction, and you read your own reference planks in the same session. Arrival readings compared with the factory's numbers alone mix two instruments and two sets of conditions.
Sources & further reading
- ISO: ISO 2813:2014, Paints and varnishes, determination of gloss value at 20°, 60° and 85° (edition 4, confirmed 2025; read November 2026)
- SIS: SS-EN ISO 2813:2014, identical adoption of ISO 2813:2014, scope including the note on other specimens (read November 2026)
- ISO: ISO 2813:1994, determination of specular gloss at 20°, 60° and 85° (withdrawn; abstract read November 2026)
- ASTM International: D523-25, Standard test method for specular gloss (read November 2026)
- ASTM International: D4449-15(2021), Visual evaluation of gloss differences between surfaces of similar appearance (read November 2026)
- ASTM International: D1729-22, Visual appraisal of colors and color differences of diffusely-illuminated opaque materials (read November 2026)
Authorship, affiliations & disclosure
Prepared from the standards bodies' published scope and significance texts listed, read on 11 November 2026; the full standards were not purchased. No standard we read sets a gloss target or tolerance for floors, so the template is blank and the worked example figures are illustrative. Have contract wording reviewed by your adviser.
Corrections & editorial informationContinue exploring.
All guides in Specs & quotesSPC flooring and sun exposure: gaps, glazing and fade evidence
SPC flooring in direct sunlight: one maker doubles its 5 mm gap to 10 mm where sun comes through glass doors. What to ask for before you approve a decor.
Read the guideAcoustic SPC flooring: how to specify and verify the sound rating
Acoustic SPC flooring claims rest on one lab build-up: ASTM E2179 rates the covering on a concrete slab, not your building. What to ask for.
Read the guideSPC flooring quotation: what the factory has not committed to
An SPC quotation fixes goods, quantity and price. Decor stock, shade, packing and lead-time start need clauses; CISG article 35 fills the rest.
Read the guide